AcadsysRevit MEP Tools

The MEP set is built around fire protection and lighting from CAD, plus hanger arrays and sequential tags. FF Network, FF Picked, Lighting from CAD, Fire Fighting Import, and Intelligent Tag Renumberer sit on the acadsysRevit tab, MEP panel. Array Hanger is launched from the General panel More drop-down and is documented here because it is an MEP coordination command.

The aim is a connected 3D fire-protection network and correctly hosted lights without tracing every pipe or placing every fixture by hand.

Fire-protection CAD mapped to Revit pipes

FF Network from CAD

FF Network reads a 2D fire-protection layout and builds a connected native Revit pipe and sprinkler network. It identifies lines and blocks, applies offsets and system definitions, and writes a reference legend that maps each CAD symbol to the Revit pipe type and diameter it became.

Ribbon: acadsysRevit tab ➤ MEP panel ➤ FF Network (CAD).

  1. Link or import the fire-protection CAD in the correct view and level.
  2. Run FF Network and select that CAD instance.
  3. Map CAD layers and blocks to Revit pipe types, sprinkler families, offsets, and system types.
  4. Generate the network. Pipes connect; sprinklers land on the blocks.
  5. Open the reference legend and confirm symbol-to-type mapping before you coordinate with architecture and structure.

Fire-protection CAD floor plan

FF Picked from CAD

FF Picked is the selective version of the same translation. Use it when only a riser, a room, or a handful of heads should come into the model, not the whole drawing.

Ribbon: acadsysRevit tab ➤ MEP panel ➤ FF Picked (CAD).

  1. Run FF Picked and pick the specific CAD fire-protection items to convert.
  2. Confirm family and system mapping for those items only.
  3. Generate. Unselected linework stays as CAD reference.

Lighting from CAD

Lighting from CAD maps 2D lighting symbols to 3D Lighting Fixture families. Elevations and orientations follow the CAD; duplicate placements are blocked so a second run does not stack fixtures.

Ribbon: acadsysRevit tab ➤ MEP panel ➤ Lighting (CAD).

  1. Select the CAD instance that holds lighting blocks.
  2. Map each symbol to a Revit lighting-fixture family and set the elevation.
  3. Generate. Check a sample room in 3D for height and rotation, then continue to tags.

Array Hanger

Array Hanger places support hangers along a pipe, duct, or cable tray at a spacing you set.

Ribbon: acadsysRevit tab ➤ General panel ➤ More drop-down ➤ Array Hanger.

  1. Click the command. It loads acadsysTools.dll.
  2. Select the host MEP element and enter the spacing between hangers.
  3. The tool follows the run and arrays the hanger families along that path in the 3D model.

Fire Fighting Import

Fire Fighting Import places fire-fighting equipment from a CSV of coordinates instead of picking each point in the view. Use it when the hydraulic or equipment schedule already lists X/Y (and elevation) for hydrants, hose reels, or similar equipment.

Ribbon: acadsysRevit tab ➤ MEP panel ➤ Fire Fighting Import.

  1. Prepare a CSV with the coordinate columns your technical contact specified for the import.
  2. Run Fire Fighting Import and select that file.
  3. Map columns to the Revit family and placement fields, then commit. Equipment lands on the coordinates rather than on a guessed CAD snap.

Intelligent Tag Renumberer

Intelligent Tag Renumberer writes sequential marks on MEP elements using spatial sort (X, then Y) so tags read in a predictable left-to-right, bottom-to-top (or equivalent) walk through the plan.

Ribbon: acadsysRevit tab ➤ MEP panel ➤ Intelligent Tag Renumberer.

  1. Select the MEP category or the elements to number (equipment, diffusers, devices, or the fire-protection set you just generated).
  2. Confirm spatial (X then Y) sorting and any prefix used on the job.
  3. Run the command. Marks update in order; a summary reports the count.

AcadsysRevit workflow from Revit to Excel

Coming next

Isometric and 3D coordination views for MEP zones are planned as a mid-September addition. They are not in the current ship set; do not expect an isometric button on the ribbon today.

A practical MEP pass

  1. Link the fire-protection and lighting CAD, and confirm levels with Level Visualiser if storeys look off.
  2. Run FF Network on the full layout, or FF Picked for a partial area.
  3. Place remaining equipment with Fire Fighting Import when you have coordinates.
  4. Run Lighting from CAD, then Array Hanger on the mains.
  5. Finish with Intelligent Tag Renumberer before you issue the set.